High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC three wire / wire type.
Shape: non shield, M30.
Detection range: 18mm.
Output configuration: PNP.
Action mode: NO. Appearance: Round/Full-guard type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-G.
Output: SPST-NC.
Lighting: LED
E2E-X10F1-Z 5M
Operating voltage: 100 VAC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Output: SPDT.
Lighting: Incandescent lamp.
Operating voltage: 24 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Sensing method: Diffuse-reflective Sensors.
Appearance: Vertical.
Connection method: Connector (M12).
Sensing distance: 700 mm .
Functions: --.
Model: NPN output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Unit classification: CJ1 Special I/O Units.
Product name: ProcessInput Units,
(Isolated-type Thermocouple Input Units).
Input points: 2 inputs.
Signal range selection:
Set separately for each input.
Signal range: Thermocouple:
B, E, J, K, L, N, R, S, T, U,
WRe5-26, PLII DC voltage: ±100 mV.
Conversion speed (resolution): Conversion,
speed: 10 ms/2 inputs, Resolution: 1/64,000.
Accuracy at ambient temperature of 25°C:
Standard accuracy: ±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 24V, 0.06A.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated.
E2E-X10F1-Z 5M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E2E-X10F1-Z 5M&select=5