Operation/resetting system: Time-limit operation/self-resetting.
Time-limit contact: DPDT (for power switching).
Time ranges: 0.04 s to 3 h.
Supply voltage: 24, 100 to 120, 200 to 230, 240 VAC (50/60 Hz);
12, 24, 48, 125, 100 to 110 VDC.
Mounting: Surface mounting (with PCB terminals).
Miniature Timer Compatible with the MY Relay.
Semi-multi power supply voltage.
Large transparent time setting knob facilitates time setting
D4SL-N4HFA-DN
A flat-blade and Phillips screwdriver can also be used for time setting.
Pin configuration compatible with MY Power Relay.
LED indication for power and output statuses.
Conforms to EMC standards.
Conforms to EN 61812-1 and approved by UL and CSA. Type: 1A contact type.
Shape: square.
Terminal shape: terminal for printed board.
Action: instantaneous.
Display mode: LED display.
Operation Department color: yellow.
Large capacity compact type push button switch.
Can also be used as a power switch with a large capacity cut.
Can be switched from micro load (minimum applicable load 1mA DC5V) to large capacity load. Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Side plunger, Standard.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard operating temperature range:
-40°C to +100°C (standard type).
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.) Appearance: Round/Projection type LED voltage-reduction lighting,
(without Voltage Reduction Unit)A22L-T.
Output: SPST-NO.
Lighting: LED.
Operating voltage: 100 VAC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).