Output: Transistor(Photocoupler).
Supply voltage: 24 to 48 VAC (50/60 Hz)/12 to 48 VDC.
Input type: No-input available.
Time range: 0.05 s to 300 h.
Operating mode(See note 2): Five multi-modes: A, B,B2, E, J (Power supply start).
Output: Transistor(Photocoupler).
Supply voltage: 24 to 48 VAC (50/60 Hz)/12 to 48 VDC.
Input type: No-voltage input.
Time range: 0.05 s to 300 h.
Operating mode (See note 2): Eight multi-modes: A, B, B2, C, D, E, G, J
D4N-4DRE
Multiple Operating Modes and Multiple Time.
Ranges. DIN 48 x 48-mm Multifunctional Timer.
A wide AC/DC power supply range greatly reduces the number,
of timer models kept in stock.
A wide range of applications with multiple operating modes,
eight modes for 11-pin models and five modes for 8-pin models.
Ecological design with reduced current consumption.
Easy sequence checking with instantaneous outputs for a zero set value.
Length of 75 mm or less when panel-mounted with a P3G-08,
Socket (H3CR-A8E, 100 to 240 VAC, 100 to 125 VDC),
PNP input models available.
Standards: UL, CSA, NK, LR, CCC, EN 61812-1, and CE Marking. Cable specifications: Fire-retardant, Robot cable.
Cable length L: 2 m.
Cable outer diameter: 6 mm.
Straight Connectors.
Minimum order: 5.
UL: Yes.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Supply voltage: 24 to 240 VAC/DC.
Control output: Contact output, SPDT (time-limit SPDT).
Four-mode Timer.
Multiple time ranges and operating modes let you cover a wide,
range of applications.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT output contacts using a switch.
Sequence checks are easily performed by setting an instanta,
neous output to 0.
Start signal control for the H3DK-M.
D4N-4DRE Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=D4N-4DRE&select=5