I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.
Analog setting: YES.Protective tubing length: W1/4 screw.
Lead wire length: 2m.
Element type: J (IC).
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers
D2S-01L
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Isolation: Photocoupler.
Zero cross function: Yes.
Indicator: Yes(Yellow).
Applicable output load (See note 1.): 90 A at 200 to 480 VAC(See note 2.).
Rated input voltage: 5 to 24 VDC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Type: no wing.
Drive shaft type: semi cylindrical plug type.
Outlet hole: 4.
Even number: 5.
Rubber material: NBR.
Head and body integration, strength and sealing performance is better, mechanical life is also significantly increased (5 million times).
The most suitable for a variety of machine tools, automatic production line of the order control.
With drain holes, oil and water can be discharged after immersion. Control supply voltage: 100/ 200 VAC; Without voltage fluctuation compensation.
Operating current: 2 to 4 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.
D2S-01L Operation manual / Instructions / Catalog download link: