Power supply voltage: 12 to 24 VDC.
Output configuration: Open-collector output (NPN).
Output code: BCD.
Resolution (divisions): 6, 8, 12.
Connection method: Pre-wired Model (1 m).
Rugged Rotary Encoder.
Absolute model.
External diameter of 50 mm.
Resolution of up to 1,024 (10-bit).
IP65 (improved oil-proof protection with sealed bearings).
Optimum angle control possible in combination with PLC or,
Cam Positioner
G5A-237PL DC12 Type: Welding / wire type, M3 screw mounting.
Driving rod: swing lever type.
Terminal specifications: with wire, the right side of the lead.
Contact specifications: 1a.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Specifications: Outputs, NPN(- common), 32 outputs.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from communications connector.
Rated I/O power supply voltage: 24 VDC.
First Board-type Terminals for Smart Slaves!
Easily modified to handle an array of I/O interfaces,
and eliminates much on-site wiring.
User boards attach easily to the DRT2-@D32BV(-1) using screws. Appearance: Rectangular (M16-J).
Lighting: Incandescent lamp, 12 VAC/VDC.
Degree of protection: IP40.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch. Name: Temperature Controller (See note 1.).
Power supply: 24 VDC.
No. of control points: 2.
Control output: Transistor output.
Auxiliary output: Transistor output: 2 pts (sinking).
Functions: Heater burnout alarm (See note 3.), Heating or heat/cool,
control is selectable (See note 4.)Event input: 1 point per Unit.
Communications functions: RS-485.
Input type (See note 5.): Platinum resistance thermometer.
New DIN Track Mounting Temperature.
Controller.
Two channels of temperature control available despite width of,
only 22.5 mm.
The Temperature Controller itself can be replaced without,
changing terminal wiring.
Use in combination with a compact Setting Display Unit to,
reduce communications programming requirements.
Front-panel LED indicators for easy operation monitoring.
Power supply and communications wiring not required between,
Units when mounted side-by-side.
CompoWay/F communications protocol supported.
UL, CSA, and CE Marking compliance.
G5A-237PL DC12 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=G5A-237PL DC12&select=5