Cable length L: A, 1.0 m; B, 0.75 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Operating: Appearance, 30-dia. head Small Push-lock Turn-reset A22E-S;
Contact Configuration, 2NC (1NC + 1NC).
Color of cap: Red.
Install in 22-dia. or 25-dia. Panel Cutout.
Direct opening mechanism to open the circuit when the contact welds
G2R-2A DC9
Safety lock mechanism prevents operating errors.
Easy mounting and removal of Switch Blocks using a lever.
Mount three Switch Units in series to improve wiring efficiency,
(with non-lighted Switch Units, three Units can be mounted for,
multiple contacts).
Finger protection mechanism on Switch Unit provided as a,
standard feature.
Install using either round, or forked crimp terminals.
Oil-resistant to IP65 (non-lighted models)/IP65 (lighted models),
A lock plate is provided as a standard feature to ensure that the,
control box and switch are not easily separated. C200H Accessory Interface Unit C200H-IP007CompoNet sensor communication unit, simplify sensor settings and management.
No program can be transmitted to the ON/OFF signal PLC (CompoNet communication from the station function).
Support setting content to the detection threshold, quantity and function of reading, writing and teaching operation (explicit message function).
The assembly is simple, just use the communication cable to connect the E3X-CRT and the amplifier next to it.
Up to 16 sensor amplifiers can be connected. Appearance: Rectangular (M16-A).
Lighting: LED without Voltage Reduction Unit, 5 VDC.
Degree of protection: IP40.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: silver.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
G2R-2A DC9 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=G2R-2A DC9&select=5