Model: CPM2C-20CDT1C-D. CPU Unit: Units with 20 I/O points.
2 Fujitsu connectors.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.
Internal clock: --.Terminal: Solder terminal.
Actuator: Short hinge lever.
Direct Current Switch with.
Built-in Magnetic Blowout.
Incorporates a small permanent magnet in the contact.
mechanism to deflect the arc to effectively extinguish it
FLV-DR6615W
Same shape and mounting procedures as the Z Basic Switches. Appearance: Unshielded, M18.
Sensing distance: 10 mm [6 to 10 mm *].
Output Model: DC 3-wire NPN.
Operation mode: NO.
Fluororesin-coated Capacitive.
Sensor with Sensitivity Adjuster.
Excellent resistance against chemicals and oil with fluororesin,
coated case.
Distance adjustment according to the sensing object using the,
sensitivity adjuster. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1.6 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive.
Lead wire length M: 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: ES1B power supply.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
FLV-DR6615W Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=FLV-DR6615W&select=5