Model: CPM2A-30CDT1-D. Power supply: DC power supply.
Output type: Transistor sourcing.
Inputs points: 18 points.
Outputs points: 12 points.Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -
F3ZN-S0522P09
Event input points: -.
Transfer output: -.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultType: rectangle.
Screen mode: level 2.
Using voltage: DC5V.
Color: white.
Color: white.
Micro design, the length of the body is only 23mm.
LED has five colors (red, yellow, green, white, and blue).
Chip LED to produce a uniform surface brightness.
From the front panel installation, more convenient. Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 25 A, 200 to 480 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.