Rated voltage: 230 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.052 A; 60 Hz, 0.045 A .
Rated input: 50 Hz, 12 W ; 60 Hz, 10 W .
Rated rotational speed: 50 Hz, 1700 r/min; 60 Hz, 2000 r/min.
Maximum flow rate: 50 Hz, 1.3 m3/min; 60 Hz, 1.5 m3/min.
Maximum static pressure: 50 Hz, 19.6 Pa; 60 Hz, 23.5 Pa.
Noise: 50 Hz, 32 dB; 60 Hz, 34 dB
F3SN-A1327P40
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Terminal (Wire connection): Push-In Plus Terminal.
Classification: Standard.
Latching lever (Test switch): No.
Rated input voltage: AC, 200V.
Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location).
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Setting range: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.
F3SN-A1327P40 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=F3SN-A1327P40&select=5