Input terminals: M3 terminals.
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 1 output (Heater Burnout Detection,
SSR Short-circuit Failure Detection, Common).
Applicable load (See note.): 2 to 35 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps
F3SN-A0547P25-01
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Conduit: JIS B 0202 G½.
Applicable cable: Cabtire cable (general purpose).
Inner diameter (D)of seal rubber: 12.5 mm.
External diameter of cable: Min, 11 mm; Max, 13 mm.
Applicable model: WL-N, WL, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2.
Connectors (SC Series).
Cabtire cables and flexible tubes with various diameters are used to,
connect machine tools and controllers with Limit Switches. To ensure,
the watertightness of the edges of the conduits, use an SC Connector,
that is suitable for the external diameter of cable and model of Limit Switch. Classification: Relay with Auxiliary Contact Block.
Structure: 4 poles + 2 poles.
Contact configuration: Relay, DPST-NO/DPST-NC; Auxiliary Contact Block, DPST-NC.
Rated Voltage: 12, 24 VDC.
Compact Electromagnetic Contactors That.
Switch 40 A at 440 VAC.
One pole carries 40 A.
UL 508 and UL 840 NC contacts (resistive 40 A 480 VAC, 60 Hz, 80,000 operations).
EN 60947-4-1 NC contacts (AC1 40 A 440 VAC, 50/60 Hz, 80,000 operations).
Ideal for supply power to industrial inverters, servo drivers, and other devices,
and switching power to motors and other equipment.
The maximum load capacity of 160 A when using 4-pole parallel connections.
EN 60947-4-1 certification for mirror contact mechanism obtained by combining,
the Relay with an Auxiliary Contact Block.
Conforms to European PV standard (VDE0126).
Approx. 30% less operation noise than a standard electromagnetic contactor.
(Approx. 100 dB reduced to approx. 70 dB.)
Approx. 50% the volume of a standard electromagnetic contactor,
to help downsize control panels.
According to OMRON investigation of IIEC-AC1 50 A specifications.
F3SN-A0547P25-01 Operation manual / Instructions / Catalog download link: