Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 outputs;
Signal range selection:
Set separately for each output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA; 1/4,00.
Conversion period: 1 ms/point.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.3% of F.S. Current: ±0.5% of F.S.
External connection: Removable terminal block
F3SJ-B0305P25-01TS
External power supply: 24 VDC +10% -15%, 200mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 24V, 0.2*3.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals.
Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A).
Operation: Alternate operation (Self-holding).
Case color: Light gray.
Output: SPDT.
Lighting: LED; 24 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup. CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP213.
4-MB memory; w/o floating-point processor.Screw pitch: M6 (P=1.0).
Lead wire length: 2 m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Actuator: Roller lever (metal lever, metal roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.
F3SJ-B0305P25-01TS Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=F3SJ-B0305P25-01TS&select=5