Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
F3SJ-A1695P30
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Specification: single phase 200V
Power: 0.4KW.
Maximum output voltage: three phase input voltage.
Rated voltage, frequency: single phase power supply 200 ~ 50/60Hz, 240V.
Cooling way: natural wind cooling.
Weight: 1.1kg.
Open loop vector control mode of low speed and high torque, rich control function and convenient distribution management network function,
Set in one of the inverter --3G3MZ.
3G3MZ series inverter for the application of frequency control and development.
Humanized design and advanced management technology, as well as OMRON a simple style of modeling, feature rich style,
Combined with the latest technical needs of users, so that it has a noble lineage and the most close to the market elements.
Covers the special features of the fan pump class, open loop vector function,
Built in noise filter and a variety of network bus,
3G3MZ will be your most economical and the most perfect choice. Type: 1a1b welding terminal.
Shape: rectangle.
Type: small load.
Action: instantaneous action (auto recovery).
With lamp: no light.
Operation Department color: red.
20mm long, with 12 round series
High brightness all one side light.
Because it is round, so easy to punch.
Miniaturization, operation feel good. Name: Safety Network Controllers.
No. of I/O points: Safety inputs, 12 *; Test outputs, 2; Safety outputs, 6.
Unit version: Ver. 1.0.
Safety inputs Test outputs Safety outputs
New Lineup for Safety Applications,
with Up to 12 Inputs.
Circuits for the required safety category are easy to build.
The safety circuits you create can be registered as templates,
and reused, for easy standardization.
A wide range of TÜV-certified templates is also available.
The NE0A operating conditions can be monitored from a,
standard DeviceNet Master.
Network distribution is possible by combining with an NE1A,
Safety Controller.
ISO13849-1 (PLe) and IEC 61508 SIL3 certification.
F3SJ-A1695P30 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=F3SJ-A1695P30&select=5