Classification: Standard models.
Rated voltage: Standard products, 100/110 or 200/220 VAC, 24 or 100/110 VDC;
Made-to-order items, 110/120 VAC, 12 or 48 VDC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany).
Different colors of coil tape for AC and,
DC models to more easily distinguish them
E2EL-C1R5E2-M3
MY(S) models with latching levers added for,
easier circuit checking. Size: 48 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: transfer output (special terminal).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Free change detection direction.
Detection direction can be according to the front, side (up and down, around 90 units) change.
Can be similar to the feeling of a limit switch installation.
Type: detection of variable terminal plate / DC type.
Shape: shield.
Detection distance: 20mm.
Output form: NO PNP + NC (dual output). Safety instantaneous output: 2 (Semiconductor).
Safety slow-speed/stopping detection output: 2 (Semiconductor).
Auxiliary output: 4(Semiconductor).
Maximum set threshold: 10 Hz.
voltage Rated: 24 VDC.
Terminal block type: Screw terminals.
Low-speed Monitoring Function Ensures.
Safety for Maintenance Work.
Motor rotation speed detected by Proximity Sensor.
Monitors and confirms that speed does not exceed the preset level.
Includes an Enabling Switch input for maintenance work.
Detailed LED indications enable easy fault diagnosis.
Safety Category 3 (EN954-1), PLd(ISO13849-1),
SIL 3 (IEC/EN 62061) certified.