Specifications: Inputs;
PNP (- common);
16 points.
I/O connections: MIL connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Very Compact 16-/32-point Remote Terminals.
Used in combination with Interface,
Conversion Boards (e.g., D-Sub) to,
connect to a wide range of interfaces.
35 x 60 x 80 mm (W x D x H)
E2E-X5Y1-Z 5M Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, E5GN-R03TC-FLK;
Resistance thermometer input, E5GN-R03P-FLK.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Category: relay output.
Points: 8 points (1a * 8).
Common line processing on the connector side: NPN correspondence (+ public).
Rated voltage: DC24V.
Achieve control cabinet miniaturization / save time,
Relay terminal for 8 point output.
Small size of 68 * high 80 * 44mm. (vertical installation)
Total wiring of connector cable.
The common end can be easily connected with the independent contact and the short circuit piece.
The G70D-SOC08 and G70R-SOC08 are connected by a short circuit chip.
When the relay does not need the tool, the relay is convenient to replace the work.
With terminal cover to prevent electric shock.
With action indication LED.
Diode for internal coil surge absorption.
DIN guide rail installation, screw mounting common.
E2E-X5Y1-Z 5M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E2E-X5Y1-Z 5M&select=5