Sensor that can be connected: Thermo-Humidity Sensor Head (ZN-THS1__-S).
Display: LCD 7-segment 5-digit 2-step display,
auxiliary information indicator display.
Measurement interval: 10 s, 20 s, 30 s, 1 min, 2 min,
5 min, 10 min, 20 min, 30 min, 1 h.
Calculation function: Instantaneous value, maximum value,
minimum value, average value.
Operating mode: Normal mode, sleep mode.
Recording mode: Continue, ring
E2E-X5ME1-Z 5M
Alarm signal output: Output to photocoupler (External power supply: 12 to 24 VDC,
Load current: Max. 45 mA) Alarm hold setting is possible.
Internal storage device: Internal memory: Approx. 8,500 data items.
External storage device: SD card (to save measured values and to save/read set, values),Recommended SD card: HMC-SD291 (manufactured by OMRON).
Power supply voltage: DC input: 24 VDC±10%, Battery: 2 AAA batteries.
Battery life: Approx. 1 year∗6 (sleep mode, measurement interval of 10 minutes, with 2 AAA nickel metal hydride batteries, with SD card not inserted).
Operating temperature range: 0 to 60°C.
Operating humidity range: 20 to 85% (no condensation).
Weight (packaged): Approx. 500 g.
Accessories: Instruction Sheet, Startup Guide CD-ROM∗7,
Alarm output connector∗8, DC cable (straight type).
Easy temperature and humidity control with an SD Card. Appearance: Rectangular (M16-J).
Lighting: LED without Voltage Reduction Unit, 5 VDC.
Degree of protection: IP40.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch. Internal I/O common: NPN.
I/O indicators: LED display (yellow). 140 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 220 g max.
Expansion functions: No.
Short-circuit protection function: Available at input,
section only (Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.
E2E-X5ME1-Z 5M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=E2E-X5ME1-Z 5M&select=5