Specification: medium capacity type.
Impact resistance: 600W.
Resistance to impact resistance: 35.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resistor.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed. Actuator: One-way action short hinge roller lever
70174-1164 SSLE10(I)
Type: Standard.
Compact, General-purpose Horizontal.
Switches.
Models for Microloads Added to Series.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.),
Incorporates a switch with a durable coil spring in a tough,
high precision case.
Compact and uses a single basic switch for applications where,
strength is required.
Models for microloads and models with operation indicators,
added to series.
Terminal protective cover can be switched to wire cable from,
either the left or right.
Sealing characteristics that meet IEC IP67 degree of protection. Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Number of beams: 88.
Protective height: 1760mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
70174-1164 SSLE10(I) Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=70174-1164 SSLE10(I)&select=5