Software for setting parameters.
A software can correspond to a variety of models
Can use the computer to compile, edit, transfer all parameters.
Reducing the time when setting the same parameters to multiple devices,
Can monitor the content of the set, the current value.
The parameters of the system can be output in the form of CSV and HTML. Safety outputs: Instantaneous, DPST-NO; OFF-delayed, --
70174-1030 SSLE10(B)
Auxiliary outputs: 1 (Solid-state).
Max. OFF-delay time: --.
Rated voltage: 24 VDC.
Complete line-up of compact units,
including OFF-delayed safety output models.
17.5 or 22.5 mm width to save mounting space.
Simple wiring using screw-less terminals.
Easy maintenance with status indicators.
One unit for various safety devices, from contact input to PNP input. Amplifier Unit.
Separate Amplifier Sensor with.
Sensitivity Adjustment.
Compact design with smaller Sensor Head.
Heat-resistance model available for application between.
-10 and 200°C. Specification: Thermocouple input (K, J, L, T, R, S, B),
ON/OFF or advanced PID control,
manual op-eration,
transistor (NPN) output, 4 loops.Output: DPDT.
Lighting: LED.
Operating voltage: 5 VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Appearance: R-shaped.
Sensing method: Through beam type (with slot).
Connecting method: Connector model (4 poles).
Sensing distance: 5 mm (slot width).
Operating mode: Dark-ON/Light-ON (2 outputs).
Indicator mode: Incident light.
Model: PNP output.
Built-in connector enables,
downsizing and easier connection.
Protective circuit for safe operation.
A built-in connector minimizes the shape and dimensional,
requirements.
Two outputs: light-ON and dark-ON.
Complete lineup including seven different shapes.
Safer operation with built-in power supply reverse polarity,
protection.
Output overcurrent protection with a thermal shutdown,
circuit (patent pending).
The indicator can be seen from many directions to enable,
installation in more locations.
Connector with lock that mates with commercially available,
connectors.
70174-1030 SSLE10(B) Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=70174-1030 SSLE10(B)&select=5