Actuator: Roller lever (resin lever, bearing roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
70170-1070 PA46-4-300-Q2-NO2-P
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Appearance: Knob-type Selector Switch A22W,
LED voltage-reduction lighting (without Voltage Reduction Unit).
Number of notches: 2 notches.
Resetting method: Automatic.
Output: SPST-NC + SPST-NC.
Operating voltage: 100 VAC.
Illumination color: R (red); Y (yellow); G (green); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Appearance: Rectangular (M16-T).
Lighting: LED without Voltage Reduction Unit, 24 VAC/VDC.
Degree of protection: IP65 oil-resistant.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch. Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
70170-1070 PA46-4-300-Q2-NO2-P Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=70170-1070 PA46-4-300-Q2-NO2-P&select=5