Safety outputs *3: Instantaneous, 2(semiconductor);
OFF-delayed *2: 2 (semiconductor).
Auxiliary outputs *4: 6 (semiconductor).
Logical AND connection: Inputs, 1 (semiconductor);
Outputs, 1 (semiconductor).
Max.OFF-delay time *1: 15 s.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
A Safety Measure for Hazardous Operations.
That Does Not Lower Productivity.
Two functions support two types of application:
Auto switching: For applications where operators work,
together with machines
3G2A9-AL004-PE
Manual switching: For applications with limited operations.
External indicator outputs enable indicating the switching status,
of two safety input devices.
Auxiliary outputs enable monitoring of safety inputs, safety,
outputs, and errors.
Detailed LED indications enable easy diagnosis.
Logical AND connection allows complicated applications in,
combination with other G9SX-series Units.
Certification for compliance with IEC/EN 61508 (SIL3), IEC/EN,
62061 (SIL3) and EN ISO13849-1 (PLe/Safety Category 4). Type: S8JC-ZS series models list.
Meet the criteria: CE (EN50178).
Configuration: power supply with cover; bottom surface mounting.
Input voltage: 350W.
Output voltage: 5VDC.
Output current: 50.0A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time. Display contents: Hexadecimal.
Type: Rear mounting.
Logic input: Negative.
Display color: Red/green/orange.
Digital Display with Wire-saving Serial.
Transmission Function (B7A Output).
Single-color (red or green) and three-color (red, green, or,
orange selectable) displays with a character height of 80, 120,
or 200 mm are available for a variety of applications and locations.
Thin design with a 39.5-mm depth for the 120-mm model is,
perfect for saving space in equipment and devices.
Decimal display including negative sign (−) display with signal,
codes is possible.