Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
A3SA-4001
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Name: Safety Network Controllers.
No. of I/O points: Safety inputs, 12 *; Test outputs, 2; Safety outputs, 6.
Unit version: Ver. 1.0.
Safety inputs Test outputs Safety outputs
New Lineup for Safety Applications,
with Up to 12 Inputs.
Circuits for the required safety category are easy to build.
The safety circuits you create can be registered as templates,
and reused, for easy standardization.
A wide range of TÜV-certified templates is also available.
The NE0A operating conditions can be monitored from a,
standard DeviceNet Master.
Network distribution is possible by combining with an NE1A,
Safety Controller.
ISO13849-1 (PLe) and IEC 61508 SIL3 certification.
A3SA-4001 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A3SA-4001&select=5