Specifications: Input, PNP (- common), 8 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: Supplied from the communications connector.
Environment-resistive (IP67) I/O.
Terminals with Troubleshooting.
Functions such as Sensor Power.
Supply Short-circuit Detection.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities
A3PJ-90A12-28
High degree of environmental resistance with dust-proof,
and drip-proofconstruction.
Power supply wiring is not required for input devices.
Connect heavy-load devices (up to 1.5 A).
Power supply wiring is not required for input devices such as sensors.
(Power supply wiring is required for output devices.)
Detects ground faults or disconnects and notifies the Master.
Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Analog (current/voltage).
Auxiliary outputs: 1.
Control output 1: Voltage output (for driving SSR).
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter. Sensor type: 3 wire DC / DC (NPN) 3 - 4 2 wire.
Input points: 6.
The I/O sensor connector for centralized wiring,
And the province of the number of processes, strong environmental resistance as the goal,
The outer control relay box.
Compact and strong centralized wiring trunk box conforming to IP67.
The corresponding sensing I/O connector mode proximity switch, limit switch,
Photoelectric switch.
With the power to show LED, action shows LED.
The installation dimensions are the same and are not related to the number of input points,
Therefore, the addition of a simple exchange.
A series of sensors with self diagnostic features are added to the product.
A3PJ-90A12-28 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A3PJ-90A12-28&select=5