Number of elements: 2.
Insulation method: Phototriac.
Rated supply voltage: 12 to 24 VDC.
Applicable motor: 0.75 kW (4.8 A), 200 to 220 VAC.
Solid State Contactors That Can Drive 3-phase Motors Frequently,
and Achieve Harmonized Protection with Thermal.
Overload Relays.
Certified for UL and CSA.
Mount with screws or to DIN tracks.
Compact monoblock construction (W: 80 × H: 100 × D: 100 mm)
A3CJ-90A1-12EG
with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.
Two-element models added to series. Cable: PUR.
Cable core number (core): 3.
Cable outside diameter: 4.3mm.
Cable outlet direction: L type.
Cable length L:10m.
Small round type waterproof connector.
Small waterproof connector can meet the requirement of protection IP67.
Is the ideal choice for a variety of FA and QA applications.
As with connector cable products, so no need for wiring operation.
Appearance: Round/Half-guard type LED voltage-reduction lighting,
(with Voltage Reduction Unit) A22L-H.
Output: SPST-NO + SPST-NC.
Lighting: LED.
Operating voltage: 200 VAC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). CPU Unit: CP1L-M CPU Units with 60 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output method, Transistor output (sinking);
Inputs, 36; Output, 24.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams.
A3CJ-90A1-12EG Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A3CJ-90A1-12EG&select=5