Analog I/O terminal with screw terminal,
block for EtherCAT communicaitons.
The input/output range can be easily,
changed by the setting with the switch.
Detachable screw terminal block,
facilitates the maintenance.
Moving average calculation function.
Settings within the range of 100μs-64ms.
(For input only.)
Disconnection detection function.
(For input only and for usage with,
1-5V or 4-20mA ranges
A22TK-2LR-11-K01)
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.Appearance: M12.
Sensing distance: 5 mm.
Connection method: M12 Connector Models.
Cable specifications: --.
Operation mode : NO .
Pin arrangement: 1: +V, 3: 0 V, 4: Control output.
Applicable connector code: B.
Model: PNP output.
Your Search for Proximity Sensors.
Starts with the World-leading.
Performance and Quality of the E2E.
Standard Sensors for detecting ferrous metals.
Wide array of variations. Ideal for a variety of applications.
Models with different frequencies are also available to prevent,
mutual interference.
Superior environment resistance with standard cable made of oil,
resistant PVC and sensing surface made of material that resists,
cutting oil.
Useful to help prevent disconnection.
Cable protector provided as a standard feature. Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
A22TK-2LR-11-K01 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A22TK-2LR-11-K01&select=5