Appearance: Knob-type Selector Switch A22W,
LED voltage-reduction lighting (without Voltage Reduction Unit).
Number of notches: 3 notches.
Resetting method: Automatic.
Output: SPST-NO + SPST-NC.
Operating voltage: 200 VAC.
Illumination color: R (red); Y (yellow); G (green); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature
A22L-GY-24-10M
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Type: Conforming to auxiliary power relay specifications.
Contact form: DPDT+DPST-NO.
Cased: Plug-in (octal pins) terminals.
Mechanically Latching Relays Based on the.
MM Power Relay.
Low power consumption due to mechanical latch for economic operation.
Relays with mixed coil specifications can be produced,
(e.g., AC setcoil and DC reset coil).
Operational response fast enough to enable pulse signal power applications.
Ambient operating temperature: –10°C to 55°C. Contact type: Standard load (250 VAC, 2 A; 125 VDC 0.4 A).
Operation: Alternate operation (Self-holding).
Output: SPDT.
Lighting: LED, 12 VDC.
Operation Unit color symbol: Enter the desired color symbol for the Pushbutton
n @. R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
Combines miniature design with distinct but soft sense of operation.
Easy panel mounting from the front and simple lamp replacement.
without tools. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
A22L-GY-24-10M Operation manual / Instructions / Catalog download link: