Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
A16L-JRM-24-1
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Sensing method: Through-beam (Emitter + Receiver).
Connection method: Connector (M8, 4 pins).
Response time: 1 ms.
Sensing distance: 60 m.
Model: NPN output .
Compact and Reliable,
Laser Photoelectric Sensor.
Safety and reliability with laser class 1 (JIS and IEC).
Product lineup includes models with distance setting without,
influence of color.
Maximum ambient operating temperature of 55°C and water,
proof construction in E3Z class. Appearance: T-shaped, slot center 7 mm.
Sensing method: Throughbeam type(with slot).
Connecting method: Connector(4 poles).
Sensing distance: 5 mm (slot width).
Output configuration: Dark-ON/Light-ON (selectable).
Indicator mode: No incident light.
Model: PNP output.
Global Standard Slot-type.
photomicrosensors with 50- to,
100-mA direct switching capacity.
Series includes models that enable switching between,
dark-ON and light-ON operation.
Response frequency as high as 1 kHz.
Easy operation monitoring with bright light indicator.
Wide operating voltage range: 5 to 24 VDC.
Models in which the light indicator turns ON for dark-ON,
operation are also available.
A wide range of variations in eight different shapes.
Flexible robot cable is provided as a standard feature. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output and long life.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
A16L-JRM-24-1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A16L-JRM-24-1&select=5