Description: OS32C with back location cable entry.
Max. Operating Range (Safety Zone): 3m.
Remarks: CD-ROM (Configuration tool) OS supported: Windows 2000,
Windows XP (32-bit version, Service Pack 3 or later),
Windows Vista (32-bit version), Windows 7 (32-bit version/64-bit version),
For configuration tool version, refer to page 23.
Compact (104.5 mm), lightweight (1.3 kg),
and easy-to-install Safety Laser Scanner
A16L-AYM-5D-1
Provides a safety circuit of PLd/Safety Category 3 (ISO13849-1) without a,
dedicated controller.
Type 3 Safety Laser Scanner complies with IEC61496-1/-3.
70 sets of safety zone and warning zone combinations are available,
supporting complicated changes in working environments.
A safety radius up to 4 m and warning zone(s) radius up to 15 m can be set.
The minimum object resolution can be changed to 30, 40, 50 or 70 mm.
The response time is configurable from 80 ms to a maximum of 680 ms.
Reference Boundary Monitoring function prevents unauthorized changes in,
the scanner position.
Minimal down time, sensor block can be replaced without the need to reprogram. Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A).
Operation: Momentary operation (Self-resetting).
Case color: Light gray.
Output: SPDT.
Lighting: LED; 24 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup. Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Can enter DC0.001mV to
A16L-AYM-5D-1 Operation manual / Instructions / Catalog download link: