Shape: rectangle.
Protection structure: IP40.
Action: alternate.
Operation Department color: white.
Column length 18mm, circular F8 series.
High brightness and with uniform light.
Round type easy opening.
Small and operation feel good. Type: square.
Screen mode: no segmentation.
Output: DPDT.
Power supply voltage: DC12V.
Contact type: standard load (AC250V, 3A; DC30V, 3A).
Operation: alternating action (self retaining)
A165L-TWA-24D-2
Operation Department color: yellow.
In the touch and the ability to protect than OMRON''s previous models have improved.
The micro volume design of 23mm is realized.
Micro design and unique combination of soft sensing.
LED has five colors (red, yellow, green, white, and blue).
Built in basic switch improves touch.
Built in basic switches in the previous model based on the OMRON to improve the protection.
Chip LED to produce a uniform surface brightness.
From the front panel installation, more convenient. Actuator: Fork lever lock (right operation).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC/2NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 35cm.
Lead wire type: Standard.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal.
A165L-TWA-24D-2 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=A165L-TWA-24D-2&select=5