Specification: Thermocouple input (K, J, L, T, R, S, B),
heater burnout alarm,
ON/OFF or advanced PID control,
manual operation,
transistor (PNP) output, 2 loops.Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 3NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards
PT08-0
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Type: S8JC-ZS series models list.
Meet the criteria: CE (EN50178).
Configuration: power supply with cover; DIN guide rail mounting.
Input voltage: 350W.
Output voltage: 5VDC.
Output current: 50.0A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time. Product name: CJ2H CPU Units.
Specifications: I/O capacity/Mountable Units(Expansion Racks),
2,560 points/40 Units(3 Expansion Racks max.) ;
Program capacity, 100K steps; Data memory capacity,
160K words(DM: 32K words, EM: 32K words × 4 bank);
LD nstructio execution time, 0.016 μs.
Current consumption(A): 5V,0.42(See note.); 24v, --.
Standards: UC1, N, L, CE.
CJ2H for high speed, high capacity.
The CJ2H Series is ideal for advanced machine.
automation needs such as those required in image.
processing inspection of electrical components and,
high speed sorting on conveyors. Setting range: 10 to 100 A AC, 20 to 200 A AC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.
PT08-0 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=PT08-0&select=5