Thermocouple type: K (CA).
Heat resistance: General use.
Outer packing: all ethylene outer wrapping (waterproof).
Compensating wire length: 1 m.
A variety of high precision temperature sensor series.
On the basis of the previous M3 screw,
An additional rod like terminal corresponding to the reduced wiring working hours.
A temperature sensor is used as a thermal sensor for a thermostat.
According to the temperature, place, the surrounding environment to be measured
PH-1 CODE 5M
Products with various shapes, shapes, lengths and terminals.
Classification: Exclusive Models.
Description: Crimping terminals.
Temperature range (See note 3.): 0°C to 300°C .
Element type: K (CA).
Conductor type: Grounded type.
Class: 2 (0.75).
Protective tubing material: --.
Terminal type: Exposed lead wires.
Page: 39.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay contact: H; PASS1c, L, each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum can be measured from 10ms to 3200sOperating method: Reversible (selectable with rotary DIP switch) between,
0 and the set value; Incrementing/decrementing A/D (command inputs);
Incrementing/decrementing B/E (individual inputs);
Incrementing/decrementing C/F (phase difference inputs).
Mounting method: Flush mounting.
Operation modes: N, F, C, R, K, P, Q (selectable with rotary DIP switch).
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
Control output: 1-stage counters: Contact (SPDT) and transistor,
output (H and L output switchable);
2-stage counters: Contact (SPST-NO) and transistor output,
(H and L output switchable).
Set value read: Continuous mode.
Memory backup: Yes/No (Selectable using DIP switch) .
Display: Yes (10-mm high 7-segment LED, Up indicator).
Models: 4 digits; 1 stage.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking.
PH-1 CODE 5M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=PH-1 CODE 5M&select=5