Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
MS4800-IP67-1480
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation, Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: L-shaped.
Cable diameter: 6.0 mm dia.
No. of cable cores: 4.
Cable core cross sectional area: 0.5 mm.
Cable length: 2 m.
DC.
Minimum order: 5.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Structure: Relays with Plug-in Terminals, With operation indicators.
Classification: Standard models Compliance with Electrical,
Appliances and Material Safety Act.
Number of poles: 2 Bifurcated.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,
joined the series.
The lineup also includes models that are compliant,
with the LR and VDE safety standards.
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 100/110 VDC).
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC).