Product name: CJ2H CPU Units.
Specifications: I/O capacity/Mountable Units(Expansion Racks),
2,560 points/40 Units(3 Expansion Racks max.) ;
Program capacity, 400K steps; Data memory capacity,
832K words(DM: 32K words, EM: 32K words × 25 banks);
LD nstructio execution time, 0.016 μs.
Current consumption(A): 5V,0.42(See note.); 24v, --.
Standards: UC1, N, L, CE.
CJ2H for high speed, high capacity
MKS3PI AC50
The CJ2H Series is ideal for advanced machine.
automation needs such as those required in image.
processing inspection of electrical components and,
high speed sorting on conveyors. Optical system: diffuse type.
Detection distance: 100 positive and negative 20mm.
Beam shape: linear beam.
Beam diameter: 3.5mm * 60 M.
Resolution: 1 m.
Cable length: 0.52m. Model: C200H-OC226N.
No. of points: 16 pts.
Specifications: 2A, 250VAC/24VDC(For resistive loads).Category: external supply 100mA DC10V.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
Relay contact: HH; PASS1c, H, L, LL: each 1a.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety ofControl output: relay output.
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).
MKS3PI AC50 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MKS3PI AC50&select=5