Conduit: JIS B 0202 G½.
Applicable cable: Cabtire cable (anticorrosive).
Inner diameter (D)of seal rubber: 7 mm.
External diameter of cable: Min, 5.5 mm; Max, 7.5 mm.
Applicable model: WL-N, WL, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2.
Connectors (SC Series).
Cabtire cables and flexible tubes with various diameters are used to,
connect machine tools and controllers with Limit Switches. To ensure,
the watertightness of the edges of the conduits, use an SC Connector,
that is suitable for the external diameter of cable and model of Limit Switch
MKS3P-5 DC110 Power supply voltage: 5 to 12 VDC.
Output configuration: Voltage outpu.
Resolution (pulses/rotation): 10, 20, 30, 40, 50, 60, 100, 200, 300,
360, 400, 500, 600; 720, 800, 1,000, 1,024, 1,200, 1,500, 1,800, 2,000.
General-purpose Encoder with.
External Diameter of 50 mm.
Incremental model.
External diameter of 50 mm.
Resolution of up to 2,000 ppr.
IP64 (improved oil-proof construction with sealed bearings).
Side or back connections are possible. Pre-wired Models with cable,
connected at an angle. Shape: socket (with open end cap).
Pole number: 26.
Pole pole number: 1.
Minimum packing unit: 80.
Printed board connector core, MIL specification standard.
Through the use of new productivity design, high reliability and low price synchronization.
A box type plug (XG4C) which is convenient for saving space is provided in the province.
A press type plug (XG4E) capable of using the relay is provided.
Will be the company''s loose wire connector (XG5) - specific plug (XG8) and PCB type.
(XG2) combined use of various types of packaging can be achieved.
Suitable for the company''s own development of a simple locking lever can make the unique plug (XG8) and,
Box type plugs (XG4C) can also be locked.
MIL specification (MIL-C-83503) standard.
Standard product conforms to the UL specification (No. E103202 File) certified products. Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
MKS3P-5 DC110 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MKS3P-5 DC110&select=5