Actuator: Roller lever: R38.
Indicator: Neon lamp.
Item: Basic.
Pretravel (PT): 25±5°.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches.
Standard-feature gold-clad crossbar contacts provide high reliability
MKS2XT-11 AC24
Applicable to either standard loads or microloads.
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models. Actuator: One-way roller arm lever (vertical).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Measuring range: 30±3mm.
Spot diameter: 60µm dia.
Static resolution: 0.25µm.
To achieve a compact Sensor Head and high-resolution measurements,
the ZW Series uses a white light confocal principle to detect objects.
This principle is described below. Appearance: Rectangular (M16-A).
Lighting: LED without Voltage Reduction Unit, 12 VAC/VDC.
Degree of protection: IP65 oil-resistant.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch. Power ratings: 90 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 3.75 A.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1).
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
MKS2XT-11 AC24 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MKS2XT-11 AC24&select=5