Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: Standard control Heating and cooling control.
Outputs(control/transfer): 2 (current + current).
Optional functions: Auxiliary outputs (SUB), 4; Event inputs, 2;
Serial communications, RS-485.
A new High-speed, High-precision Digital.
Controller that is Programmable!
Create up to 32 programs with up to 256 segments total.
Coordinated operation for up to four channels with one Digital Controller
MKS2PN AC120
0.01°C High resolution for Pt input.
High-speed sampling at 50 ms.
Settings easily made from a computer using the CX-Thermo.
RoHS compliance for world-wide application. Type of drive rod: roller plunger type.
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (2NC).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used. Release key type: Special release key.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+2NC/1NO.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Separate Amplifier Sensor with.
Sensitivity Adjustment.
Compact design with smaller Sensor Head.
Heat-resistance model available for application between.
-10 and 200°C.
MKS2PN AC120 Operation manual / Instructions / Catalog download link: