Size: 48 x 48mm.
Control output 1: relay.
Auxiliary (alarm) output: 3.
Transfer output: -.
Event input: 2.
Communication: -.
Disconnection detection: 1.
Power supply voltage: AC100 ~ 240V.
The white PV (current value) with excellent visibility shows the segment to make the confirmation work more easily.
Eye-catching white + industry''s largest display size
The black and white display and the industry''s largest display size to achieve excellent visibility
M2PA-90A12-24EW
No matter from which angle or in the natural lighting environment, the dark scene,
Can quickly and accurately confirm the current value.
Displays the current value (PV/ white), the target value (SV/ green) and the progress of the program (PRG, SEG/ yellow).
Can be viewed at the same time, there is no need to switch the display, so as to improve the efficiency of operations. Appearance: Round/Projection type LED lighting,
(without Voltage Reduction Unit)A22L-T.
Output: SPST-NO.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Operation: Momentary operation (self-resetting).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.