OMRON LY4 AC100/110 Pirce

No PHOTO
Brand: OMRON
Country: JAPAN
Name:
Market price: U.S.$ 18.18
(The following are the market open price not sales price!)
OMRON LY4 AC100/110
Input capacity: 32 points.
Internal I/O common: NPN.
ON voltage: 15 VDC min. (between each in,
put terminal and the V terminal).
OFF voltage: 5 VDC max. (between each in,
put terminal and the V terminal).
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0 LY4 AC100/1105 ms,
1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms.
(Default setting: 1ms)
Number of circuits per common: 32 points/common.
Input indicators: LED display (yellow).
Isolation method: No isolation.
I/O power supply method: Supplied from unit power supply.
Input device supply current: 50 mA/point.
Unit power supply current consumption: 230 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 220 g max.
Expansion functions: No.
Short-circuit protection function: Available.
(Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance. The main body: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
LY4 AC100/110 Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=LY4 AC100/110&select=5


...more relevant model market price >>>>
Related products
OMRON
Miniature power relay
MY2N-GS AC100/110
OMRON Miniature power relay MY2N-GS AC100/110
Action indicator: LED action indicator,
OMRON
Miniature Power Relays
MY2 DC100/110
OMRON Miniature Power Relays MY2 DC100/110
Classification: Standard models. Rated
OMRON
Miniature Power Relays
MY2N-CR AC100/110
OMRON Miniature Power Relays MY2N-CR AC100/110
Classification: Models with uilt-in dio
OMRON
Solid State Relays
G3F-202SN-VD AC100/110
OMRON Solid State Relays G3F-202SN-VD AC100/110
Isolation: Photocoupler. Zero cross fun