Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock
HL-1HPA100
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors. Number of beams: 106.
Protective height: 2120mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Operating modes: Flicker ON start.
Supply voltage: 100 to 240 VAC/100 to 125 VDC, 24 to 48 VAC/12 to 48 VDC.
0.05 s to 300 h models: 8-pin models.
DIN 48 × 48-mm Twin Timers.
Wide power supply ranges of High Voltage 100 to 240 VAC/100,
to 125 VDC and Low Voltage 24 to 48 VAC/12 to 48 VDC.
ON- and OFF-times can be set independently and so,
combinations of long ON- or OFF-time and short OFF- or ON,
time settings are possible.
Twenty-four time ranges from 0.05 s to 300 h depending on the,
model to be used.
Models with a flicker ON start or flicker OFF start are available.
Easy sequence checks through instantaneous outputs for a,
zero set value at any time range.
Length, when panel-mounted with a Socket, of 80 mm or less.
11-pin and 8-pin models are available.
HL-1HPA100 Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=HL-1HPA100&select=5