Contact type: Standard load (250 VAC, 3 A; 30 VDC, 4 A).
Operation: Alternate operation (Self-holding).
Case color: Light gray.
Output: SPDT.
Lighting: Incandescent lamp; 6 VDC/VAC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting)
H5CX-A11S
included in lineup. Rated voltage: 200 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2200 r/min.
Maximum flow rate: 50 Hz, 0.9 m3/min; 60 Hz, 1.0 m3/min.
Maximum static pressure: 50 Hz, 43 Pa; 60 Hz, 42 Pa.
Noise: 50 Hz, 42 dB; 60 Hz, 43 dB.
Weight: Approx. 1120 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Number of inputs: 16 pts.
Input Voltage: 12 V DC.
Input Current: 6 mA.Sensing method: Reflective type.
Sensing distance: 0 to 3 mm.
Output configuration: Turns ON when wafer carrier is present.
Cable length: 2 m.
Photomicrosensors for detecting,
wafer-carrier mounting.
The mounting position is set with a pedestal.
The contact surface with the wafer carrier uses a special chemical,
resistant fluororesin.
The unique optical system enables stable detection of almost all,
wafer-carriers.
Light modulation effectively reduces external light interference.
Utilizes talc-free clean cables. Actuator: Shaft.
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBB contacts are also available.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
H5CX-A11S Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=H5CX-A11S&select=5