Isolation: Phototriac coupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 20 A at 180 to 400 VAC.
Rated input voltage: 12 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks.
Downsizing achieved through optimum design of heat sink.
Mounting possible via screws or via DIN track.
Close mounting possible for linking terminals.
(Except for G3PA-260B-VD and G3PA-450B-VD-2
G9S-321-T10 AC100)
Applicable with 3-phase loads.
Replaceable power element cartridges.
Comply with VDE 0160 (finger protection),
with a dielectric strength of 4,000 V between input and load.
Certified by UL, CSA, and VDE (reinforced insulation). Appearance: Knob-type Selector Switch A22W,
LED voltage-reduction lighting (without Voltage Reduction Unit).
Number of notches: 3 notches.
Resetting method: Automatic.
Output: SPST-NO.
Operating voltage: 100 VAC.
Illumination color: R (red); Y (yellow); G (green); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Size: 96 × 96 mm.
Control type: 2-loop control.
Control mode: 2-loop standard control, 2-loop heating and cooling control,
Single-loop cascade control, Single-loop control with remote SP,
Single-loop proportional control.
Outputs(control/transfer): 4 points: Pulse voltage (2 points) and
Pulse voltage/current (2 points).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, None; Serial communications, Yes.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming.
G9S-321-T10 AC100 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=G9S-321-T10 AC100&select=5