Input type: PNP input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Digital rotating pulse meter with high speed measurement for 50kHz.
Action determine the color, can switch the green / Red 2 kinds of color display
G9S-301 DC24
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFF pulse signals, the most up to 50kHz of high-speed pulse measurement.
Rotation measurement of high speed rotating objects can be carried out.
SupportModel: C200H-OA224.
No. of points: 12 pts.
Specifications: 0.5 A, 250VAC.Appearance: F-shaped.
Sensing method: Through beam (with slot).
Sensing distance: 5 mm (slot width).
Output configuration: Light-ON Dark-ON (2 outputs).
Connection method (Cable length): Pre-wired model with standard cable (1 m).
Output type: NPN.
Meeting Customer Needs with.
Ultra-compact Sensors that Mount.
with M3 Screws.
Mount using M3 or M2 screws.
Reliable sensing slot depth of 6.5 mm.
Indication of sensing window for easy confirmation of,
insertion depth.
Bright indicator for confirmation from many directions.
Both light-ON and dark-ON outputs provided.
All models available with either standard cable or,
flexible robot cable.
Load short-circuit protection circuit provided.E3Z-G62-S0SHW-E2 is selected for use with 1 optical axis and 15 axis type
Prevent mutual interference function, EN standard specifications
Groove type photoelectric sensor without optical axis adjustmentType: open type.
Structure: DIN guide rail mounting type.
Capacity: 100W.
Output voltage: 5V.
Output current: 20A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
G9S-301 DC24 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=G9S-301 DC24&select=5