Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output)
G3SD-Z01P-US DC12
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Specifications: Inputs; PNP (- common);
16 points.
I/O connections: M3 screw terminals.
Rated internal circuit power supply voltage:
Supplied from Basic Unit.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals.
Easy wiring with no sharing of terminals.
Easy-to-understand wiring locations.
No relay terminal block terminals required.
Detachable cassette-type circuit sections. Type: KM50-C intelligent monitor.
Application circuit: single phase 2 wire system AC100 ~ 240V; single phase 3 wire system AC100/200V;
Three-phase 3 wire system AC100 ~ 240V.
Power supply voltage sharing: sharing AC100 to 240V with the measured voltage input.
Shape: 48 (H) * 48 (W) * 84 (D).
Communication: RS-485.
Protocol: ompoWay/F: the number of communication nodes 31 Modbus: the number of communication nodes 99 (shared).
Energy classification function (industry initiative).
Show the 3-STATE function through the 3 color display energy saving room for improvement.
Equipped with easy to grasp the room for energy saving and convenient 3-STATE function.
3-STATE function refers to the use of the state power, the cumulative power is divided into operation / standby / stop 3 types of functions.
2 and 3-STATE function linkage, can operate / standby / stop 3 points for individual output
(determine the object can be selected from power, current, voltage)
Pulse input count, pulse input ON time, unit power consumption measurement.
G3SD-Z01P-US DC12 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=G3SD-Z01P-US DC12&select=5