Appearance: Unshielded.
Sensing distance: 20 mm.
Output configuration: DC 3-wire, NPN.
Model: Operation mode, NO.
Standard Flat Sensors in.
Many Different Variations.
Only 6 mm thick yet provides a sensing,
distance of 3 mm (TL-W3MC1).
Aluminum die-cast models also available. Setting range: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Current Monitoring for
XS2W-D421-Y81-F
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SPDT output contacts, 5 A at 250 VAC (resistive load).
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Type: rectangle.
Screen mode: 2 short axis segmentation.
Light way: LED.
Power supply voltage: 28V
Operating part left color: blue.
Operating part right color: white.
Square 40mm body of the indicator light series.
The same type as the A3S series button switch.
Easy to install from the front panel and no tools to carry out the lamp replacement. Decision circuit, sensor power supply, the integration of the same period and linear sensor combination is easy to use.
4-20mA analog input, PASS/NG determine the output.
Large capacity sensor power supply, 200mA DC12V power abundant.
Built in synchronization input function.
30mm super wide. Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed roller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
XS2W-D421-Y81-F Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=XS2W-D421-Y81-F&select=5