Specification: medium capacity type.
Impact resistance: 1200W.
Resistance to impact resistance: 17.
The use of resistance to consume the motor regenerative energy, thereby reducing the time to slow down.
Alarm output terminal of braking resistor.
When the temperature relay of the braking resistor is activated, a circuit for cutting the main power supply of the frequency converter is formed. Actuator: Plunger
XS2W-D421-A81-A
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Specifications: Inputs; NPN (+ common); 16 inputs.
I/O connections: Sensor connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage:
Supplied from the communications connector.
Includes Sensor Connector That Conforms to,
Industry Standards And Can Be Used to Connect.
Sensors with Pre-wired Cables without Using,
Special Tools.
Equipped with the standard Smart Slave,
functions that provide powerful.
preventative maintenance and,
troubleshooting capabilities.
Digital I/O Terminal compatible with,
industry-standard sensor connectors.
Connect sensors easily without special tools.
Reduce time required for wiring.
Load short-circuit detection. Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
XS2W-D421-A81-A Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=XS2W-D421-A81-A&select=5