E32-D73-S type: environment resistant; heat resistant,
Specialty: heat resistant: 400,
Bending radius (mm): R25.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsNumber of beams: 143.
Protective height: 1440mm.
Model: PNP output.
Easy-to-use Safety Sensor Ideal for.
Simple On/Off Detection Applications.
Provides simple safety functions - saving TCO
XR2A-2811-N
by reducing errors.
Simple wiring with only 4 wires.
Fast response time of 5 ms. Case color: Black.
Lighting method: LED; 5 VDC.
Display color symbol: R.O.G.W.
Large Rectangular-bodied Indicators.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting),
included in lineup. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Auxiliary outputs: None.
Control output 1: Current output.
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
XR2A-2811-N Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=XR2A-2811-N&select=5