Category: incidental cover type.
Structure: bottom surface mounting type (300/600/1500W type forced cooling with built-in fan).
Capacity: 300W.
Output voltage: 5V.
Output current: 60A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function
XG4U-6404
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Support finger touch protection to prevent electric shock.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable when the fan is replaced by the customer.)
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
"
Model : CVM1D-BI102.
10-slot.Name: Heat/Cool Temperature Control Module.
Model: C200H-TV101.
Sensor: Platinum resistance thermometer: JPt100, Pt100.
Control output: Transistor output.Size: 45 × 35 mm.
Type: Plug-in.
Control method: ON/OFF operation.
Control output: Relay.
Power supply voltage: 100 to 240 VAC.
Ideal for Simple Built-in Control.
A high switching capacity of 10 A at 250 VAC enables,
direct load switching.
A sensor is provided to enable immediate application.
Sockets with finger protection (PTF14A-E) or without,
finger protection (PTF14A) can be used.
Simple operation and settings. Even simpler with digital models. Measuring current: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC.
Supply voltage: 24 VAC/DC.
Ideal for current monitoring for,
industrial facilities and equipment.
Monitor for overcurrents or undercurrents.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output relay can be switched between normally open and,
normally closed.
Process control signal (4 to 20 mA) and commercial CT input,
(0 to 1 A or 0 to 5 A) supported.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.
XG4U-6404 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=XG4U-6404&select=5