Type: Standard type.
Enclosure: surface type.
30 years of best-selling products new upgrade in the reservation,
Based on the basic functions to achieve a compact.
The installation dimensions of the surface type remain unchanged, the volume ratio of the volume ratio of the square body is reduced,
Half. (excluding AGD-U2)
Built in digital filter to reduce the impact of high frequency interference, to achieve a higher accuracy,
Leakage monitoring
XG4T-3004
The output point consists of 1c1a * monitoring circuit, an external signal based on contact,
Remote monitoring and alarm output of each monitoring circuit.
Cube embedded type also built-in buzzer. (except AGD-U2) alarm output,
Optional external buzzer.
After the upgrade of all products can choose automatic reset, manual reset.
(AGD-N5, AGD-NY5, AGD-N52)Size: 96 × 96 mm.
Control type: Position-proportional control(1 loop).
Control mode: Single-loop position-proportional control(See note.).
Outputs(control/transfer): Relay output(1 open, 1 close).
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 4; Serial communications, No.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4.0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming. Release key type: Special release key.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+2NC/1NO.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection.
XG4T-3004 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=XG4T-3004&select=5