Conduit: ½-14NPT.
Applicable cable: Cabtire cable.
Inner diameter (D)of seal rubber: 9 mm.
External diameter of cable: Min, 7.5 mm; Max, 9.5 mm.
Applicable model: D4A-@N.
Connectors (SC Series).
Cabtire cables and flexible tubes with various diameters are used to,
connect machine tools and controllers with Limit Switches. To ensure,
the watertightness of the edges of the conduits, use an SC Connector,
that is suitable for the external diameter of cable and model of Limit Switch
VAL2 Output: SPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 24 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. E3T-SR11 detection methods: Regression reflection type,
Connection mode: lead wire,
Output status: ON,
Output mode: NPN output,
Long distance photoelectric sensor to realize the regression reflection
Type 10m distance setting 2mAppearance: Shielded, M18.
Sensing distance: 5 mm.
Output configuration : DC 2-wire.
Operation mode: NO.
Inductive Profoximity Sensor with.
Chemical-resistant Fluororesin Case.
Housing and mounting are made of Fluororesin resistant to chemicals.
Maximum sensing distance: 10 mm. Appearance: Shielded, M18.
Sensing distance: 8 mm.
Model: Output configuration: NPN NO.
Long-distance Proximity Sensor.
Long-distance detection at up to 30 mm enables secure mounting,
with reduced problems due to workpiece collisions.
No polarity for easy wiring with DC 2-wire models.
Cable protector provided as a standard feature. Power ratings: 480 W.
Input voltage: 2-phase and 3-phase, 380 to 480 VAC, 450 to 600 VDC.
Output Voltage: 24 V.
Output current: 20 A.
Boost Current: 24 A.
Worldwide 3-phase Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market.
Wide input range for worldwide applications:
380 to 480 VAC (320 to 576 VAC).
Possible for 2-phase input usage*:
380 to 480 VAC (340 to 576 VAC).
When using the 960 W at 2-phase input, the power rating is 768 W.
DC input can be available*:
450 to 600 VDC (450 to 810 VDC).
Excluding 960 W.
High efficiency 91% typ. at 480 W model.
Wide operation temperature range: –40 to 70°C.
Power Boost function at 120%.
Meets LR maritime standards.
EMS: Conforms to EN 61204-3.
EMI: EN61204-3 Class B.
RoHS Compliant.
Three years Warranty!
VAL2 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=VAL2&select=5