Number of inputs: 8 pts.
Input Voltage: 100 to 120V DC.
Input Current: 5 mA.Head material: Plastic*1.
Release key position: Bottom.
Release key type: Special release key(resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 3NC+1NC/1NO
V680S-HMD64-PNT
Conduit opening: Pg13.5.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available. Power ratings: 30 W.
Output voltage: 12 V.
Output current: 2.5 A.
Boost current: --.
Newly Released High-capacity 240-W Models in S8EX-series Lineup.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models.
Lineup of models with from 5 to 48-VDC output.
voltages.
All Models.
Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models).
The top class in industry for compact size.
Boost current output (some models excluded). Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
V680S-HMD64-PNT Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=V680S-HMD64-PNT&select=5