OMRON
Home >> Price >> OMRON >> V-16-1A5 Pirce
Brand sort

OMRON V-16-1A5 Pirce

No PHOTO
Brand: OMRON
Country: JAPAN
Name:
Model: V-16-1A5
Market price: U.S.$ 4.26
(The following are the market open price not sales price!)
next one: OMRON V-16-1C25
Last one: OMRON V-161-1C4
OMRON V-16-1A5
Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: Standard control Heating and cooling control.
Outputs(control/transfer): 2 (current + current).
Optional functions: Auxiliary outputs (SUB), 10 (Seenote 1.);
Event inputs, 10; Serial communications, RS-485.
A new High-speed, High-precision Digital.
Controller that is Programmable!
Create up to 32 programs with up to 256 segments total V-16-1A5
Coordinated operation for up to four channels with one Digital Controller.
0.01°C High resolution for Pt input.
High-speed sampling at 50 ms.
Settings easily made from a computer using the CX-Thermo.
RoHS compliance for world-wide application. Type: S8JC-ZS series models list.
Meet the criteria: CE (EN50178).
Configuration: power supply with cover; DIN guide rail mounting.
Input voltage: 50W.
Output voltage: 24VDC.
Output current: 2.1A.
Economic type power supply S8JC-Z additional models,
The new power S8JC-ZS has a CE certification mark to market.
Product features: reduce material costs;
Export machinery to be used to meet specific safety standards;
Through the DIN guide rail installation, significant savings in time. Appearance: there are F4 shell, R2 shell.
Circuit structure and open circuit mode: single contact 1C, voltage, no voltage, DC circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit element time to adjust the degree 0.25-0.5-1-2-3-4-5-6-7-8-9-10,
12 nominal action time to adjust the scale of 10300% over current, 10s plus or minus 5%,
700% over current, 1.52s plus or minus 7%; instantaneous elements, nominal action time 200% over current 40ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: closed circuit, 110V 5A L/R=0ms1000 DC220V times, 10A L/R=0ms1000 DC times;
30W (DC 110V 1A closed, L/R=25ms1000), 80VA (AC 220V 1A) cos with =0.1 1000.
Contact: AC110V, 7.5A, COS with =0.4; (AC250V 825VA)
DC24V, 5A, L/R=7ms (maximum 50W time DC125V).
Automatic experiment: No.
Display: start display (LED), after the time display (LED).
Output display, trip (R phase and T phase) manual reset type, instant manual reset type.
Excitation surge current suppression (fuzzy inference): -.
Quality: about 1.3KG (R2 shell), about 1.8kg (F1 shell), about 3.3kg (D2 shell).
External: Mount Searl N1.5.
Static type over current relay K2CA-D type, attention to the protection of the coordination of static type OCR.
The protection coordination between OCR and MCCB is simple.
1 sets of three-phase protection, can save space and manpower.
Compared with the plate movement start display, through time display, make maintenance and inspection becomes simple.
The display of the accident occurrence phase is used to facilitate the inspection after the accident.
Reduce the consumption of VA, reduce the burden of converter.
V-16-1A5 Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=V-16-1A5&select=5


...more relevant model market price >>>>
Related products
Related download