A reliable basic switch with an external lever
Can use 0.1A, 6A, 11A, 16A and 21A models,
All models have a self - cleaning connection.
Custom leverage can be used externally or internally,
And 2 fixed positions of the external lever.
Consistent with EN61058-1 and UL1054.
Model composition:
D3V- - - - - - - - - - - - -
The 4 5 6 7 8 9
Rated value
AC250V 21: 20 (4) A
AC250V 16: 16 (3) A
AC250V 11: 11 (3) A
AC250V 6: 6 (2) A
AC125V 0
UMYM5-1000-04001A 01:
Contact interval
No mark: 1mm (Gap F)
G:0.5mm (Gap G)
Driving rod
No mark: needle button type
1: short swing rod type
2: swing lever type
3: long swing rod type
R 4: type swing lever type
5: ball short swing rod type
6: ball type
The installation position of the sensors
No mark: internal installation, the button switch is far from the reference position
M: external installation, the button switch is far from the reference position
K: external installation, the button switch is close to the reference position.
Contact the specifications
SP DT 1:
SP ST-NC 2:
SP ST-NO 3:
The terminal specification
A: welding terminal
#187 C2: type terminal
#250 C: type terminal
The maximum operating force (OF)
5: 1.96 N
4A: 1.23 N
4: 0.98 N
3: 0.49 N
2: 0.25 N
Note that the numerical value is a needle like button type.
We take the size of mounting hole
No mark: 3.1mm
2.9mm K:
9 special code
No mark: Standard
H: high temperature (125 degrees C)
E: special rating: 21 (8) ASize: 48 x 48mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.
UMYM5-1000-0400 Operation manual / Instructions / Catalog download link: